User Tools

Site Tools


panda:se

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
panda:se:index [2016/05/25 14:20] Astrid Schneidewindpanda:se [2021/05/19 16:57] (current) – [5.5T magnet MAG-V-7.5T] Astrid Schneidewind
Line 1: Line 1:
-=== Sample Environment ===+====== Sample Environment ======
  
 Sample environmemt on PANDA is available and supported mainly from MLZ SE pool. Please find the values of sample space and height you need in the drawings provided by pdf-files.  Sample environmemt on PANDA is available and supported mainly from MLZ SE pool. Please find the values of sample space and height you need in the drawings provided by pdf-files. 
  
-== * CC Cryostat (liquid-free)== +===== Helium vapor pressure =====
  
-liquid-free CC is the working-horse on PANDA for experiments above 2.5K. To reduce backgrounda vacuum chamber wich large diameter is available.+For NV managementuse phase diagram, e.g.:
  
-{{:panda:se:cc_cold_head.pdf|}}+http://groups.physics.umn.edu/zudovlab/manuals/cryogenics/Helium_Vapor_Pressure.png
  
-{{:panda:se:cc_cold_head_in_large_vacuum_chamber.pdf|}} 
  
-== * He3 Insert (for liquid-free CC Cryostat)==+===== Cryostats =====
  
-**(exchange by actual drawing with right numbers!!!!)** +==== CC Cryostat (liquid-free==== 
-{{:panda:se:3he_stick_frm_04092008.pdf|}}+
  
-== * Dilution Insert (for liquid-free CC Cryostat)==+liquid-free closed cycle (CC) cryostat is the working-horse on PANDA for experiments above 2.5K and below 320K. To reduce background, a vacuum chamber with large diameter is available. To mount the sample, we need to open the whole cryostat, which means that sample exchange need additional 0.5 - 1 hour for drying the cryostat (depending on the inner temperature before exchange). This cryostat is dedicated to PANDA so it is available all the time and easy to use.
  
-== 7.5T magnet MAG-V-7.5T (room tempbore for liquid-free CCr Cryostat, possible in combination with 3He/diution inserts)==+  {{:panda:se:cc_cold_head.pdf|[drawing] CC cryostat}} 
 +  * {{:panda:se:cc_cold_head_in_large_vacuum_chamber.pdf|[drawing] CC cryostat in vacuum chamber}}
  
-http://www.mlz-garching.de/instrumente-und-labore/probenumgebung/magnetische-felder.html+==== CCR cryostat ====
  
-== * 5T magnet JVM1-5.0T (liquid-He cooledbase temp1.5K, possible in combination with Kelvinox-diution insert)==+For reaching the lower (or higher) temperatures than CC cryostat can dowe use CCR top loading cryostatsThey can be also booked without a special insert, if user needs quick sample exchange during the experiment. They cannot reach 2.5K as CC cryostattheir minimum temperatures are normally around 3K. 
  
-http://www.mlz-garching.de/instrumente-und-labore/probenumgebung/magnetische-felder.html+  * {{:panda:se:image_manager_content_noresize_cut-through-standard-ccr.png?linkonly|[drawing] schamatic view of the CCR cryostat}}
  
-== * 15T magnet (liquid-He cooled, base temp1.5K, possible in combination with Kelvinox-diution insert)==+Following special inserts are available for CCR cryostat from the poolThey need to be booked in advance.
  
 +=== He3 Insert (for CCR) ===
  
 +He3 insert can reach temperatures from 300K down to 0.35K. Cooling time to base temperature is 3-4hours. Currently running He3 insert is very automatized and is used on PANDA very often.
 +
 +  * {{:panda:se:frm2-inserts-drawing_febr_2015.pdf|[drawing] dimensions of available He3 and dilution inserts}} - On PANDA is normally used **3He-2 Ex-Halle** insert
 +
 +=== Dilution Insert (for CCR) ===
 +
 +He3 insert can reach temperatures from 1K down to 80mK. Without running the dilution, it is possible to reach temperatures above 3K. But reaching stable temperatures between 1-3K is not possible. Cooling time to base temperature is roughly 6 hours. Running dilution insert requires serious effort of the sample environment team.
 +
 +  * {{:panda:se:frm2-inserts-drawing_febr_2015.pdf|[drawing] dimensions of available He3 and dilution inserts}} - On PANDA is normally used **Mischer 2** insert
 +
 +==== He-cooled Variox (possible in combination with Kelvinox-diution insert) ====
 +Description will be added.
 +  * {{:panda:se:jvc-variox.pdf|[drawing] Variox cryostat}}
 +  * {{:panda:se:kelvinox_im_variox.pdf|[drawing] Kelvinox insert in Variox cryostat}}
 +
 +===== Magnets =====
 +Several magnets are available, operated by MLZ sample environment groups. Please find the details below. 
 +==== 5.5T magnet MAG-V-7.5T ====
 +
 +disturbs NEPOMUC operation, can be used only in exceptional cases
 +room temp. bore for liquid-free CCr Cryostat, possible in combination with 3He/diution inserts
 +
 +  * Maximum field is only 5.5T, non-shielded
 +  * [[http://www.mlz-garching.de/instrumente-und-labore/probenumgebung/magnetische-felder.html|description of the magnets at MLZ webpage]]
 +
 +==== 5T magnet JVM1-5.0T ====
 +
 +cannot be provided now.
 +liquid-He cooled, base temp. 1.5K
 +
 +  * {{:panda:se:sca0195_customer_approval_14mar17.pdf|[drawing] JVM-5T magnet}}
 +  * [[http://www.mlz-garching.de/instrumente-und-labore/probenumgebung/magnetische-felder.html|description of the magnets at MLZ webpage]]
 +
 +==== 12T magnet symmetric ====
 +
 +liquid-He cooled, recondensing, base temp. 1.5K, possible in combination with Kelvinox-diution insert
 +
 + 
 +  * {{ :panda:12t_zeichnung_.pdf |}}
 +
 +==== 8T magnet asymmetric ====
      
 +liquid-He cooled, recondensing, base temp. 1.5K, possible in combination with Kelvinox-diution insert
 +
 +{{ :panda:8t_zeichnung_.pdf |}}
panda/se.txt · Last modified: 2021/05/19 16:57 by Astrid Schneidewind