====== Sample Environment ====== | ====== Sample Environment ====== | ||
- | RESEDA offers a variety of sample environments, | + | RESEDA offers a variety of sample environments, |
- | You can find a selection | + | You can find an overview |
- | to discuss your specific needs with RESEDA' | + | It is always recommended to discuss your specific needs with RESEDA' |
- | figure out the optimum | + | who are always happy to figure out the perfect |
+ | |||
+ | {{ : | ||
===== Cryostats ===== | ===== Cryostats ===== | ||
- | One of the standard sample environments at RESEDA is a top loading CCR cryostat with an 80mm diameter.\\ | + | One of the standard sample environments at RESEDA is a top loading CCR cryostat with an inner diameter |
- | The temperature range that can be accessed with this cryostat is between 3.5K and 310K. \\ | + | The temperature range that can be accessed with this cryostat is between 3.5K and 320K. \\ |
Due to it's large diameter, sample size is usually not an issue with this set-up. \\ | Due to it's large diameter, sample size is usually not an issue with this set-up. \\ | ||
When considering sample size it is however a good idea to consult our [[https:// | When considering sample size it is however a good idea to consult our [[https:// | ||
- | |||
- | |||
==== Cryostat Inserts ==== | ==== Cryostat Inserts ==== | ||
- | * < | + | * < |
+ | to extend the temperature range to 500mK a < | ||
+ | The cooling time to base temperature is approximately 4h. | ||
* Dilution fridge insert: | * Dilution fridge insert: | ||
- | + | for even lower temperatures | |
- | + | this temperature range are needed as well, it should be taken into account that it will take quite some time to move the temperature across \\ | |
- | === He3 Insert (for CCR) === | + | the < |
- | + | Cooling time to base temperature | |
- | He3 insert can reach temperatures | + | 6h are needed. \\ |
- | + | Measurements in this temperature range take a lot of preparation time and it is therefore paramount to discuss them with your instrument scientist\\ | |
- | * {{: | + | as soon as possible to allow a smooth beamtime. |
- | + | ||
- | === Dilution Insert (for CCR) === | + | |
- | + | ||
- | He3 insert can reach temperatures from 1K down to 80mK. Without running the dilution, it is possible | + | |
- | + | ||
- | * {{: | + | |
===== Magnets ===== | ===== Magnets ===== | ||
+ | ==== Horizontal Field ==== | ||
- | ==== 5.5T SANS Magnet ==== | + | ==== Vertical Field ==== |
- | + | ||
- | ==== 2.2T Magnet | + | |
- | ==== 12T Magnet ==== | ||
- | ==== 3T Magnet ==== | ||
- | ===== Ovens ===== | + | ===== Furnaces |